4 Core 50/125 MM Çelik Zırhlı Tek Tüplü LSZH Fiber Optik Kablo-OM3 FO104M3-LSZH
ÖZELLİKLER |
BİRİM |
DEĞERLER |
TEST STANDARTLARI |
TENSILE STRENGTH AT BREAK |
kN |
>1.2 |
EN 60794.1.E1 |
BREAKING TENSILE STRENGTH |
kN |
>1.5 |
EN 60794.1.E1 |
CRUSH RESISTANCE |
N/cm |
>200 |
EN 60794.1.E3 |
REPEADING BENDING RADIUS |
mm |
<20xD |
EN 60794.1.E6 |
SINGLE BENDING RADIUS |
mm |
<15xD |
EN 60794.1.E6 |
TORSION |
+90° C,8 |
possitive |
EN 187 000 M 508 |
IMPCAT |
kN |
>1 |
EN 187000 M 504 |
TEMPERATURE |
EN 60794.1.E11 |
||
OUTER SHEATH | |||
DENSITY |
g/cm³ |
>20 |
ASTM D 638 |
TENSILE STRENGTH AT BREAK |
N/mm² |
>400 |
ASTM D 638 |
ELONGATION AT BREAK |
% |
2/10 |
ASTM D 1693 |
E.S.C.R. (%10 lgepal C-630) |
>500 hours |
2/10 |
ASTM D 746 |
BREAKING COLD |
<-75°C |
2.5+0.5 |
ASTM D 1603 |
CARBON BLACK RATE |
% |
<0.950 |
ASTM D 792 METOT A |
OXIGEN INDUCTION TIME |
200°C |
>25 |
IEC 811.4.2 B |
TUBE GEL | |||
DENSITY (25°C) |
g/cm³ |
+0.05 |
DIN 51 757 |
DROP POINT (24 HOUR) |
°C |
aooropriate |
IEC 811.5.1 B |
DRIP POINT (24 HOUR) |
°C |
>70 |
REA PE 39 |
FLASH POINT |
°C |
>230 |
ISO 2592 |
OIL SEPERATION (150°C, 24 HOUR |
% |
0 |
FTM STD 791 C |
VOLATILITY |
% |
<2 |
FTM STD 791 C |
WATER ARMOUNT |
% |
<0.05 |
DIN 51 777 |
ACID VALUE (100°C) |
% (mg KOH/g) |
<0.01 |
DIN 53 402 |
ABRATION |
|
posıtıve |
IEC 811.5.1 |
PENETRATION (25°C / -30°C) |
1/10 mm |
>150 |
ISO 2137 |
OXIGEN INDUCTION TIME (180°C) |
minute |
>20 |
IEC 811.4.2 B |
100-500V (100°) |
Ω x m |
>10 |
ASTM D 1169 |
100-500V (23°) |
Ω x m |
|
ASTM D 1169 |
LOSE TUBE |
>10,11 |
|
|
DENSITY |
g/cm³ |
1.31+0.03 |
ISO 1183 |
WATER ABSORPTION (23°C) |
% |
<0.45 |
DIN 53 495 |
TENSILE STRENGTH AT BREAK |
N/mm² |
<30 |
ISO 527 |
ELONGATION AT BREAK |
% |
>50 |
ISO 527 |
E-MODULUS |
N/mm² |
>2200 |
ISO 527 |
SHORE |
Shore D |
>78 |
DIN 53 505 |
MELTING TEMPERATURE (DSC) |
°C |
>220 |
ISO 3146 C |
LIN. THERMAL EXT. COEFF. (-23<<+80°C) |
°K-1 x10-4 |
<1.3 |
|
E-GLASS YARN |
|
|
|
DENSITY |
g/cm³ |
offered |
offered |
TENSILE STRENGTH AT BREAK |
% |
offered |
offered |
ELONGATION AT BREAK |
N/mm² |
offered |
offered |
E-MODULUS |
% |
offered |
offered |
ARMOURING |
|
|
|
STEEL THICKNESS |
nm |
0.155±0.015 |
ASTM A 623 M |
TENSILE STRENGTH AT BREAK |
N/mm² |
>300 |
ASTM E 6892 |
ELONGATION AT BREAK |
% |
>15 |
ASTM E 6892 |
THICKNESS OF COATING |
nm |
>0.050±0.01 |
ASTM A 623 M |
DC RESISTANCE |
ohm/km |
<40 |
ASTM A 6892 |
''ORing Networking Fiber ürünleri Ömür Boyu Garantilidir.''